Ex 8V limit switch boxes in vestamide housing |
|
 |
|
|
 |
Ex 8V limit switch boxes , zone 1, 2 + 21, 22 for rotary actuators
|
|
|
 |
|
|
|
 |
|
This standard limit switch boxes in vestamide housing are specialy using for the chemical and petrochemical industry. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs. For example SJ 3,5-N, SJ 3,5-SN, SJ 3,5-S1N, NJ2-12GK-N, NJ2-12GK-SN ... . More technical informations check the following chart.
|
|
 |
|
Ex 8V limit switch boxes in vestamide housing |
|
 |
|
|
 |
Ex 8V limit switch boxes, zone 1, 2 + 21, 22 for linear actuators
|
|
|
 |
|
|
|
 |
|
This standard limit switch boxes in vestamide housing are specialy using for the chemical and petrochemical industry. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs. For example SJ 3,5-N, SJ 3,5-SN, SJ 3,5-S1N, NJ2-12GK-N, NJ2-12GK-SN ... . More technical informations check the following chart.
|
|
 |
|
|
|
 |
|
|
|
 |
|
Ex 8V limit switch boxes in aluminium housing |
|
 |
|
|
 |
Ex 8V limit switch boxes, zone 1, 2 + 2, 22 for rotary actuators
|
|
|
 |
|
|
|
 |
|
This standard limit switch boxes in aluminium housing are specialy using for the iron and steel industry. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs. For example SJ 3,5-N, SJ 3,5-SN, SJ 3,5-S1N, NJ2-12GK-N, NJ2-12GK-SN ... . More technical informations check the following chart.
|
|
 |
|
Ex 8V limit switch boxes in aluminium housing |
|
 |
|
|
 |
Ex 8V limit switch boxes, zone 1, 2 + 21, 22 for linear actuators
|
|
|
 |
|
|
|
 |
|
This standard limit switch boxes in aluminium housing are specialy using for the iron and steel industry. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs. For example SJ 3,5-N, SJ 3,5-SN, SJ 3,5-S1N, NJ2-12GK-N, NJ2-12GK-SN ... . More technical informations check the following chart.
|
|
 |
|
|
|
 |
|
|
|
 |
|
Ex 8V limit switch box in stainless steel housing |
|
 |
|
|
 |
Ex 8V offshore limit switch box, zone 1, 2 + 21, 22 for rotary actuators
|
|
|
 |
|
|
|
 |
|
These stainless steel limit switch boxes are specialy using for the offshore industry. All parts of these limit switch boxes are corrosion resistant. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs, for example SJ 3,5-N or SJ 3,5-SN. This limit switch box technology are established and well tried on the valve world. More technical details check here: offshore limit switch box for rotary actuators [368 KB]
|
|
 |
|
Ex 8V limit switch box in stainless steel housing |
|
 |
|
|
 |
Ex 8V offshore limit switch box, zone 1, 2 + 21, 22 for linear actuators
|
|
|
 |
|
|
|
 |
|
These stainless steel limit switch boxes are specialy using for the offshore industry. All parts of these limit switch boxes are corrosion resistant. The 8V DC intrinsic safe inductive sensors are from Pepperl+Fuchs, for example SJ 3,5-N or SJ 3,5-SN. This limit switch box technology are established and well tried on the valve world. More technical details check here: offshore limit switch box for linear actuators [369 KB]
|
|
 |
|
|
|
 |
|
|
|
 |
|
|
|
 |
|

|
|
 |